If toilets and toilet compartments are meant to be used by children the standards provides suggestions and guidance in lieu of using the adult guidelines.
Grab bar height ada toilet.
Ada accessible bathrooms for kids should have grab bars at heights of 18 27 inches depending on the primary age group using the bathroom.
In addition the grab bar heights for children are found in 609 4.
Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum from the rear wall and extending 54 inches 1370 mm minimum from the rear wall.
Clearance above the grab bar.
3 costs associated with providing accessible telephones such as relocating the telephone to an accessible height installing amplification devices or.
The toilet paper dispenser shall be mounted below the grab bar at a minimum height of 19 inches 485 mm.
For ada and ansi nothing can be installed directly behind the grab bar.
Recessed dispensers are allowed within the 12 305 mm space above and 1 38 mm space below and at the end of a grab bar for ada the recessed dispenser must be flush.
If the grab bar is 36 high a non recessed toilet paper dispenser located above the bar must have an outlet at exactly 48 high to accommodate both the max.
Bottom of the bar located 39 990 mm minimum and 41 1040 mm maximum above the floor.
See also ada requirements for seats grab bars in toilet stall requirements.
For 3 and 4 year olds bars should be 18 20 inches from the floor for 5 to 8 year olds bars should be 20 25 inches and for 9 to 12 year olds grab bars should be 25 27 inches.
A vertical grab bar 18 455 mm minimum in length mounted along the side wall.
The guidelines for children s toilets are found in ada tas section 604 9.
A 42 inches 1065 mm minimum length grab bar is required on the side wall spaced a maximum of 12 inches 305 mm from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height of 33 36 inches 840 915 mm.
The toilet paper dispenser shall be mounted below the grab bar at a minimum height of 19 inches 485 mm.
Two grab bars shall be installed on the back wall one located in accordance with 609 4 and other located 8 inches 205 mm minimum and 10 inches 255 mm maximum above the rim of the bathtub.
Example single user toilet room.
However ansi allows for 6 mm projection in the allowed area.
Each grab bar shall be 24 inches 610 mm long minimum and shall be installed 24 inches 610 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall.
Grab bars enlarging toilet stalls insulating pipes or installing accessible faucet controls.
The height of the toilet seat shall be 17 to 19 inches 430 485 mm above the finished floor.